Report No. 27935R2 August 7, 2001 Client: Rust Bullet, LLC Reference: Mr. Robert Murphy Subject: Comparison of Specialty Coatings for Rust Control Products.
Nine coated metal test panels were submitted by the Client
and identified by individual numbers 1 through 9. A tenth, uncoated,
panel was submitted as a control. Request: Expose the submitted test panels to the environmental
sequence listed in the submitted “Test Protocol”. Test No. 1: Method: All nine of the coated test panels were scribed
down to the metal substrate and exposed to 168 hours of accelerated
weathering in an Atlas Weatherometer model 18W type HH. The apparatus
and operation was in accordance with the procedures set forth in ASTM*
G-153. The uncoated control panel was similarly exposed. Test No. 2: Method: After accelerated weathering all ten of the submitted
test panels were thermal cycled (ASTM D-2337) between 160°F and
–20°F. Two cycles were performed each consisting of 3 hours. Test No. 3: Method: After thermal cycling all ten test panels were
placed in a salt fog/spray chamber for 500 hours (3 weeks). The chamber
was operated in accordance with the procedures set forth in ASTM B-117
except actual sea water was used in place of standard salt water. Test No. 4: Method: After 500 hours of salt fog/spray the remaining
four test panels were submerged in sea water (ASTM D-870) for 336 hours
(2 weeks). Test No. 5: Method: Original specimens of panels 2, 5, 6, and 8 were
evaluated for abrasion resistance in accordance with the procedures
set forth in ASTM D-4060 Taber using 1000 gram load and CS-10 abrasive
wheels.
Note: Panel #5 was considered a failure and was eliminated from further testing. Test No. 6: Method: Original specimens of panels 2, 6, and 8 were evaluated
for flexibility of the coating in accordance with the procedures set
forth in ASTM D-522 method B using a 3/8” mandrel. Test No. 7: Method: Original specimens of panels 2, 6, and 8 were evaluated
for chip resistance by the rapid deformation procedure (ASTM D-2794). Test No. 8: Method: Original specimens of panels 2, 6, and 8 were evaluated
for adhesion in accordance with the procedure set forth in ASTM D-3359. * American Society for Testing &
Materials |
||||||||||||

Rust Bullet
- Rust Bullet Application
- About Rust Bullet
How Rust Bullet Works - Rust Bullet
FAQ
POR15® and >Wasser®
Brand System Comparison - MSDS
Data
Corrosion Engineering
Data - Home
and Farm Uses
Commercial
Uses - Car
Rust Prevention - Rust Resources
Rust Bullet, LLC ©2002 - 2004 All rights
reserved.