Printed from
National
Testing Standards, Inc., Certificate: Test No. 1:
Method: All nine of the coated test panels were scribed
down to the metal substrate and exposed to 168 hours of accelerated
weathering in an Atlas Weatherometer model 18W type HH. The apparatus
and operation was in accordance with the procedures set forth in
ASTM* G-153. The uncoated control panel was similarly exposed.
Results: None of the nine coated test panels exhibited
any degradation of the integrity of the coating. The uncoated
control panel exhibited light surface rusting.
(Report
No.27935R2 National Testing Standards, Inc.)
|